swimming pool accessories price in Bangladesh, swimming pool equipments price in Bangladesh, indoor swimming pool maker in Dhaka, water pool maker bd, Bangladeshi swimming pool company, swimming pool tiles fitting company in Bangladesh, best Swimming Pool Equipment Supply, Construction & Installation company in Bangladesh, Best Swimming Pool Builders company in BD, Equipment Suppliers company in BD.
GENERAL NOTES FOR SWIMMING POOLS AND SPAS
1. Buried Poly Ethylene (PE) pipe gas lines shall be 18” below finish grade or in an approved recessed channel with
14 gauge insulated tracer wire; Galvanized malleable iron, galvanized wrought iron, or galvanized steel, are
prohibited materials for use underground. TESTING: TEST PRESSURE SHALL BE 3lbs FOR 10
MINUTES.
2. Gas lines 6” or more above finish grade may be of Schedule 40 iron pipes without wrapping.
3. Piping installed above ground shall be securely supported and located where it will be protected from physical
damage. (Sec. 1211.1 U. P. C.)
4. Anti-entrapment type drain covers required per ASME/ANSI Standard A 112.19.8.
5. P-traps are required for all pools and spas.
6. Swimming pools or spas shall have at least two circulation drains per pump that shall be hydraulically balanced
and symmetrically plumbed through one or more “T” fitting, and that are separated by a distance of at least three
feet in any dimension between the drains.
7. Gas shutoff valve to be within 3 ft. of equipment are required for PE pipe. (Sec. 1210 U.P.C.)
8. Equipment venting to be a minimum of 4 ft. from building openings (Sec. 806.7 U.M.C.) and 4 feet from the
property line. (Sec. 416.6 Uniform Swimming Pool Code)
9. Non metallic electrical conduit shall be 18” below finish grade (P.V.C.) and 6” when below concrete and bonded
per Art. 680 N.E.C. (See table 300-5 for more information)
10. Hydrostatic relief valve is required for all pools and spas unless a soils report states otherwise.
11. Electric Pool Water Heaters. All electric pool water heaters shall have the heating elements subdivided into
loads not exceeding 48 amperes and protected at not more than 60 amperes.
The opacity of the branch-circuit conductors and the rating or setting of over current protective devices shall not
be less than 125 percent of the total load of the nameplate rating. (Art. 680-9 N.E.C.)
12. Underground Wiring Location. Underground wiring shall not be permitted under the pool or within the area
extending 5 feet horizontally from the inside wall of the pool. (Art. 680-10)
a. Exception No. 1: Wiring necessary to supply pool equipment permitted by this article shall be allowed within
this area.
Page 1 of 5
CITY OF LAKE FOREST 25550 COMMERCENTRE DRIVE LAKE FOREST, CA 92630 • (949) 461-3470
Page 2 of 5
CITY OF LAKE FOREST 25550 COMMERCENTRE DRIVE LAKE FOREST, CA 92630 • (949) 461-3470
b. Exception No. 2: Where space limitations prevent wiring from being muted 5 feet or more from the pool
such wiring shall be permitted where installed in rigid metal conduit, intermediate metal conduit or a nonmetallic
raceway system. All metal conduits shall be corrosion-resistant and suitable for the location. The
minimum burial depth shall be as follows:
Wiring Method Minimum Burial (Inches)
Rigid Metal Conduit 6
Intermediate Metal Conduit 6
Rigid Nonmetallic Conduit Approved for Direct
Burial without Concrete Encasement 18
Other Approved Raceways* 18
13. Underwater lighting fixtures shall be per Article 680-20 N.E.C.
14. Fencing shall be a minimum of 5 feet high with 4 inches maximum between vertical members, and 2 inches
maximum between horizontal members. Bottom of fence to be within 2 inches of firm soil or 4 inches to pavement.
A self-closing and self-latching gate, swinging away from the pool, with the latch at a minimum of 5 feet
above grade. A 48” vertical non climbable portion in fence is required.
15. Pool and spa lights to be G.F.I. protected.
16. A convenience outlet shall be provided no closer than 10’ and no more than 20 feet from water’s edge and shall be
G.F.I. protected (Per Nec 680-6).
17. Hose bibs must have anti siphon.
18. Paint all exposed ABS and PVC with a water base synthetic Lucite paint unless piping is labeled UV resistant.
19. Handrail is required for two or more steps leading to a slide. If over 30” in height then guardrails are required. If
there is a permanent barrier, then this requirement can be omitted at the inspector’s discretion.
20. Swimming pool heating system must contain the following measures mandated by the State Energy Regulations:
b. A permanent weatherproof plate or card, easily readable, giving instructions for the energy efficient operation
of the swimming pool for the proper care of swimming pool when a swimming pool cover is used.

Peerage gallery
79. saudia super market, Framget, dhaka -1215
info@steambathbd.com
www.steambathbd.com
mobile/whattsapp: 01817500456 -01740145694

Comments Add new

Add new comment
No comments added yet. Be first to leave comment!

Seller's info

Company
Registered on February 24, 2018

Listing location

Bangladesh, Dhaka City, Tejgaon
79 Saudia Super Market, Framget Dhaka -1215

Seller's email address

Close
liamg@49yrellagegareep.com
- you cannot copy & paste mail, you need to rewrite it
- do not send spam
- ask only questions related to this product
- do not be rude

 Get it on Google Play

Hello! Sign in to get more.
Home Search My account My alerts My personal info My listings Mail us
Refine search
Keyword
Category
Location

Region

City

Pictures
Price

Price:

-
Advanced
Clean search