HEYER PORT+(Multifunctional Emergency Transport Ventilator)
Price
2072800.00 Tk
Category
Listing ID
#43511
Publish date
October 13, 2018
Last modification
October 13, 2018
Additional information
Description
It helps optimize quality of care & patient comfort, improving patient outcomes. One device adresses diverse ventilation requirements, fully covering various situations.
Integrated with Versatile Ventilation Modes
Pressure control & volume control mode
Invasive & Non-Invasive ventilation
SPONT/PSV, CPAP modes
Manual Respiratory Maneuver: Manual breath, Inspiratory hold
Enhancements:
FiO² 40% to 100% continuously adjustable
Waveform display: Pressure-time, Flow-time
Alarm silence, Initial start-up test
Features:
Simple operation
Compact design
Reliable performance
Waveform display and ventilation parameter monitoring
Electronically controlled PEEP
Acoustic and visual alarms, anti-crash design
Direct access to critical settings and patient data.
Ventilation settings
Ventilation frequency (RR) Apnea ventilation, 1 to 120 bpm, 1 to 40 bpm (SIMV)
I:E ratio 4:1 to 1:10
Inspiratory time 0,1 - 15 s
Tidal volume (VT) 0-2000ml
Inspiratory Flow 0,1 – 90 L/min
PEEP (option) 0 to 30mbar (or hPa or cmH2O)
TP (option) 0 to 5s
PSV (option) 0 to 50 cmH2O
PCV (option) 5 to 50 cmH2O
CPAP (option) 0 to 30 cmH2O
O2 concentration (FiO2) 40 to 100 Vol%
Trigger sensitivity Flow / Pressure
Flow 2-30 mbar (or hPa or cmH2O)
Pressure -20 to 0 mbar (or hPa or cmH2O)
MADE IN GERMANY
Integrated with Versatile Ventilation Modes
Pressure control & volume control mode
Invasive & Non-Invasive ventilation
SPONT/PSV, CPAP modes
Manual Respiratory Maneuver: Manual breath, Inspiratory hold
Enhancements:
FiO² 40% to 100% continuously adjustable
Waveform display: Pressure-time, Flow-time
Alarm silence, Initial start-up test
Features:
Simple operation
Compact design
Reliable performance
Waveform display and ventilation parameter monitoring
Electronically controlled PEEP
Acoustic and visual alarms, anti-crash design
Direct access to critical settings and patient data.
Ventilation settings
Ventilation frequency (RR) Apnea ventilation, 1 to 120 bpm, 1 to 40 bpm (SIMV)
I:E ratio 4:1 to 1:10
Inspiratory time 0,1 - 15 s
Tidal volume (VT) 0-2000ml
Inspiratory Flow 0,1 – 90 L/min
PEEP (option) 0 to 30mbar (or hPa or cmH2O)
TP (option) 0 to 5s
PSV (option) 0 to 50 cmH2O
PCV (option) 5 to 50 cmH2O
CPAP (option) 0 to 30 cmH2O
O2 concentration (FiO2) 40 to 100 Vol%
Trigger sensitivity Flow / Pressure
Flow 2-30 mbar (or hPa or cmH2O)
Pressure -20 to 0 mbar (or hPa or cmH2O)
MADE IN GERMANY